Remotec ZXT-120 Dokumentacja Strona 10

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 29
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 9
10
airconditionersinaroom
areused
- extendthebatterylifeby
disablingtheSurroundIR
Emitters
(default)
33
(0x21)
ACfunction“SWING”control 0x00:SWINGOFF
0x01:SWINGAUTO
(Default)
Learnlocationstatus Bitmask=1,learn
locationhaslearn
data.Otherwise,Bit
mask=0
SeefigureLearn
locationasbelow
35
(0x23)
Onbelowexample,location1,7,8,12,16arelearned
data.
6 45 3 2 1 07
0 00 0 0 1 01
BitMaskByte1
Location07
BitMaskByte2
Location815
BitMaskByte3
Location1623
BitMaskByte4
[Reseved]
6 45 3 2 1 07
0 10 0 0 0 10
6 45 3 2 1 07
0 00 0 0 0 10
6 45 3 2 1 07
0 00 0 0 0 00
Figure:Learnlocation
37
(0x25)
Sensortemperature
compensation
(Thisparameterisusedto
compensatethetemperature
errorattemperaturesensor)
Temperatureoffset
value.
Formula:
Displaytemperature
=sensorreading
value+offsetvalue
(unit=degreeC)
0x00=0
o
C(Default)
0x01=1
o
C
0x02=2
o
C
0x03=3
o
C
0x04=4
o
C
0x05=5
o
C